Smartvent can be modified to provide intake ventilation for new roofs or re roofs through the fascia board for low slope roof with less than a 4 12 pitch.
Low sloped roof ventilation.
To properly ventilate a low slope roof we ve created a special assembly method which allows the installation of ridge vent and eliminates associated roof leaks.
I m trying to vent a 1 12 roof that has not been vented.
So that probably means you are going to use a modified bitumen roof or something like that for the 5 12 low slope flat roofs.
For over generations multi residential flats buildings were constructed in north american with low slope roofs.
Where wood shingles or shakes are used a minimum 1 4 inch 6 mm vented air space separates the shingles or shakes and the roofing underlayment above the structural sheathing.
The top of the roof meets the wall of the house and the 2 sides also meet walls.
I don t know what the minimum slopes allowed for your type of metal roof materials are.
Look at our fasciavent which has been designed more specifically for metal roofs and provides the intake ventilation for flat to 16 12 pitches.
This attic space was typically vented via static air vents.
This clearance is more than sufficient to prevent any water from entering your house through the ridge vent.
November 19 2014 9 08pm 1.
If your low roof that ends at a wall high side is a pitched roof say 4 12.
An airspace is left above the ceiling insulation and below the under side of the roof decking and the roof is vented either around its perimeter with soffit vents a flat roof or the roof may be include intake venting at its lower edge through a soffit and outlet venting through a half ridge vent or similar outlet vent along the roof s uppermost edge a low sloped roof.
If you want a low slope roof without any spray foam or rigid foam there are only two approaches that will work as far as i know.
About 12 x 18.
You need to create an unvented roof assembly.
So it is essentially boxed in on 3 sides.
The roof design included an interstial space of 1 5 to 2 meters between the ceiling and roof deck.
One of my goals this year is to learn about ventilation for my customers so we can make good recommendations for them.
Last year i ran into several flat and low slope roofs with vents on the top of them in different scenarios 2 12 slope barrels and near dead level.
We raised a ridge vent by 2 inches from the roof surface.
Check the specs for the exact minimum.
I m a flat low slope roofer.
On a windy day the vent s turbine mechanism spins which moves hot attic air up and out.
Ventilate at the gable ends and insulate the ceilings of the space if not vaulted.
Hi all in new.
You need to make sure that you have an air space of at least 6 inches between the top of your insulation layer and.