Set the quinn therm qrfr ply insulation boards onto a wide 30mm bead of vapour resistant sealant applied to the upper surface of all the joists and cross noggins.
Insulation between flat roof joists.
This is used for refurbishment e g.
Staple a 4 to 8 mill.
Thread the twine between the joists attaching it to the sides of the joists with drywall screws or roofing nails.
This method of insulation can also be used to upgrade the thermal performance of an existing roof without affecting the waterproofing system.
How to insulate a flat roof.
Both these variants require different approaches to insulation which will be covered in this guide.
How to install insulation in a flat roof with timber deck insulated above the joists.
A cold deck flat roof will typically require insulation to be installed between the roof joists to comply with building regulation requirements.
Lay your chalk line across your two pencil marks and snap a line across all of the joists in between.
If insulation is placed on top of the flat roof joists and as such the joists are not fastened to the boarding above the depth to width ratio should not be greater than 4.
The rule of thumb for foil faced boards like thermapitch tp10 or kooltherm k7 in this scenario is that you can have no more insulation under the joists than you have between the joists.
Unless the joists are exceptionally deep there is also likely to be a requirement to install insulation to the underside of the joists as the upper 50mm of joist space is usually required to be left clear for ventilation purposes.
The insulation boards should be laid with the plywood face up.
The insulation is below the deck but above the plasterboard.
The insulation should not bulge past the joist faces.
1 2 timber strength class and joist size.
Insulation is placed in between the joists underneath the roof surface above.
It is preferred to have the bulk of the insulation between the joists to reduce any risk of condensation.
A cold flat roof is one where the insulation is between or between and below the roof joists.
Measure and cut 2 by 4 inch lumber to fit the gaps between each set of joists.
Refurbishing an existing timber joisted flat roof which has no insulation.
The majority of domestic cold flat roofs use insulation between and under the joists.
Between and under joists.
Depth to width ratio should not be greater than 6.
Measure and mark the joists at each end of the roof about 4 feet in from the edge.
Good question theoretically when building a warm roof the vaper control layer goes on the warm side of the insulation.